LV XLPE insulation lead sheathed non-armoured cable


LV XLPE insulation lead sheathed non-armoured cable
Standard: IEC 60502
Capacity: 2000km/m
Voltage: 600/1000v
Application: used for mortgage installation system of power supply,can be installed in the indoor or outdoor application,can also be laied in the pipeline,but also buried directly
   


XLPE insulation lead sheathed non-armoured cable
Application:
 
This cable is mainly used for mortgage installation system of power supply, can be installed in the indoor or outdoor application, can also be laied in the pipeline, but also buried directly, can be used in substation, power station, industrial zone with no mechanical damage. Lead sheath can prevent corrosion of aromatic hydrocarbon compounds.
 
Structure:
XLPE insulation lead sheathed cable
Conductor
Multi strand round (non compact type and compact type) or fan-shaped conductors, 2 class conductor, according to IEC 60228, conductor is solid, 1 class conductor, according to the IEC 60228, BS EN60228, also can be provided according to the customer demand.
 
insulation
 
XLPE insulation, thickness follows the 60502-1 IEC, continuous working temperature is 90°C.
 
PVC insulation thickness, followed by 60502-1 BS, IEC 6346 PVC insulation class A, followed by 60502-1 IEC, or T11 class, followed by BS 6346.
PVC insulation can reach the level of SASO 1694, continuous working temperature is 85°C, can also be provided according to customer needs.
 
Inner sheath
 
2, 3, 4 core cable, non absorbent material surrounded and filled with extrusion PVC lining lead sheathed extrusion lead alloy "e" class in the sheath, follow the BS 12548 thickness according to IEC 60502-1. other thickness may also be provided in accordance with customer demand.
 
Outer sheath
 
Outer sheath is the extrusion PVC, ST2, PVC class, follow the 60502-1 IEC, or 9 class, follow BS 6346/5467.
Some special types of PVC, such as flame retardant PVC, ant PVC, anti rodent PVC, anti oil PVC, as well as a number of special sheath materials, such as LLDPE, MDPE, HDPE, LSF, CPE, can be provided according to customer needs.

LV single core XLPE insulation lead sheathed non-armoured cable parameter:
 
Cross-sectional area Conductor diameter Insulation thickness Lead sheath thickness Sheath thickness Cable diameter Cable weight
mm2 mm mm mm mm mm Kg/Km
1x10 rm 4 0.7 1.2 1.4 16 715
1x16 rm 5 0.7 1.2 1.4 17 825
1x25 rm 6.3 0.9 1.2 1.4 19 1025
1x35 rm 7.4 0.9 1.2 1.4 20 1150
1x50 rm 8.8 1 1.2 1.4 21 1350
1x70 rm 10.6 1.1 1.2 1.5 23 1675
1x95 rm 12.4 1.1 1.2 1.5 25 2025
1x120 rm 14 1.2 1.2 1.6 27 2425
1x150 rm 15.5 1.4 1.3 1.7 29 2800
1x185 rm 17.4 1.6 1.4 1.7 31 3400
1x240 rm 20.3 1.7 1.4 1.8 35 4250
1x300 rm 22.7 1.8 1.5 1.9 37 5000
1x400 rm 25.4 2 1.6 2 42 6250
1x500 rm 28.8 2.2 1.7 2.2 46 7725
1x630 rm 30.4 2.4 1.8 2.3 48 9275