3C+1C MV Aerial Bundled Conductor (ABC) Cables


3C+1C MV Aerial Bundled Conductor (ABC) Cables
Standard: IEC 60502
Capacity: 2000km/month
Voltage: MV
Application: used for secondary overhead lines on poles or as feeders to residential premises.
   


3C+1C MV abc cable
Phase Conductor:Circular compacted stranded H68 aluminium to BS2627
Conductor Screen:Extruded semi-conductive layer
Insulation:XLPE
Insulation Screen:Extruded semi-conductive layer
metallic Screen(optional):Copper wire screen or copper tape screen
Separator:Semi-conductive swellable tape
Outer Sheath:HDPE
Support Conductor:Galvanized steel wires
Assembly:Three XLPE insulated screened cores are bundled around the galvanized steel wires in a right hand lay
 
Standard:
Basic design to IEC 60502/AS/NZS 3599-1 standards
 
Application:
Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises.
3C+1C MV abc cables

IEC 60502 6.35/11 kV Aerial Bundled Cable for Overhead Distribution Lines:
 
Number of Cores x Nominal Cross Section Phase Conductor Messenger Suspension Unit Continuous current rating at 300C ambient temp
Stranding Nominal Sectional Area Maximum Conductor Resistance Stranding Nominal Sectional Area Breaking Load
No.×mm² No.×mm mm² Ω/Km No.×mm mm² KN   A
3X50 + 1X25 19/1.78 50 0.641 7/3.0 50 60 116
3X70 + 1X50 19/.14 70 0.443 7/3.15 50 62 210
3X95+ 1X50 19/2.52 95 0.32 7/3.0 50 60 173
3X185+1X120 37/2.52 185 0.164 7/4.67 120 150 259
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 365
3X240 +1X50 61/2.25 240 0.125 7/3.15 50 62 500

IEC 60502 19/33 kV Aerial Bundled Cable for Overhead Distribution Lines:
 
Number of Cores x Nominal Cross Section Phase Conductor Messenger Suspension Unit Continuous current rating at 300C ambient temp
Stranding Nominal Sectional Area Maximum Conductor Resistance Stranding Nominal Sectional Area Breaking Load
No.×mm² No.×mm mm² Ω/Km No.×mm mm² KN   A
3X50 + 1X50 19/1.78 50 0.641 7/3.0 50 60 165
3X150+ 1X50 37/2.25 150 0.206 7/3.0 50 60 315
3X185+1X70 37/2.52 185 0.164 7/3.57 70 91 355
3X70 +1X50 19/2.14 7 0.443 7/3.15 50 62 250
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 370


Previous:4/6 AWG Duplex Service Drop       Next:0.6/1KV and Below Parallel Bunched Overhead Insulated Cable