Product List
Hot Product
  • Low smoke low halogen flame retardant control cable
  • Shielded power cable
  • Welding Cable
  • 4/6 AWG Duplex Service Drop
  • Metal shielded power cable
  • TR-XLPE Insulated URD Cable
  • Low smoke low halogen flame r
  • Shielded power cable
  • Welding Cable
  • 4/6 AWG Duplex Service Drop
  • Metal shielded power cable
  • TR-XLPE Insulated URD Cable
Projects

NYCWY Cables

Release time:2018-01-12 11:03 hit:


Cu conductor XLPE insulated power cable
Application and description

NYCWY cables are commonly used for power supply and are well suited for underground laying, especially in consumer networks, power plants, control boards and test data systems. Overall, this cable is suitable for use where electrical and mechanical protection is required and can be installed in open air, underground, in water, indoors and in cable ducts. Corrugated Concentric Conductors (CW) can be used as a neutral, protective or ground wire. Also available
Grounding protection for the shield. Its special corrugated concentric conductor structure, may not cut down the person and the conductor in the situation, may connect with more cable joints, therefore also guaranteed the cable good movement.
 
Standard and certification
VDE0276- 603, CENELEC HD603 S1, IEC 60502
 
Cable structure
-bare copper conductor solid or stranded, conductor type
10-16 mm² round solid conductor (re).
10-25 mm², multiple round (rm),
35-240 mm², Multi-sector sector conductor (sm)
- Complies with DIN VDE 0295 cl.1 / cl.2, BS 6360 cl.1, IEC 60228, HD 383
- PVC insulated Class DIV4, complying with HD 603.1
- Color coding to DIN VDE 0293-308, 0276- 603 / HD 186
PVC lining
Concentric conductors: corrugated copper wire and spiral copper tape
- PVC outer sheath DMV5, complying with HD 603.1
 
Technical characteristics
Operating voltage: 600/1000 V.
- Test voltage: 4000 V.
- Dynamic bending radius: 15 x Ø
- Static bending radius: 12 x Ø
- Operating temperature at application: -5º C ~ + 50º C
- Fixed installation temperature: - 40º C ~ + 70º C
- Reachable temperature when shorted: + 160º C
- Flame retardant: IEC 60332.1
- Insulation resistance:> 100 MΩ x km
Guaga Core No.×Section Area ( #×mm²) Nom.
Insulated Thickness ( mm) 
Nom.
Outer Dia. Min.-Max.
Cu Weight (kg/km) Nom. Cable Weight ( kg/km)
8 2 x 10.0 re / 10.0 19 312 650
6 2 x 16.0 re / 16.0 21.5 489 850
4 2 x 25.0 rm / 25.0 24.5 763 1210
8 3 x 10.0 re / 10.0 19.5 408 730
6 3 x 16.0 re / 16.0 22 643 1000
4 3 x 25.0 rm / 16.0 26 902 1550
4 3 x 25.0 rm / 25.0 26 1003 1600
2 3 x 35.0 sm / 35.0 27.5 1402 1850
2 3 x 35.0 sm / 16.0 27 1190 1750
1 3 x 50.0 sm / 50.0 29.5 2000 2450
1 3 x 50.0 sm / 25.0 29 1723 2250
2/0 3 x 70.0 sm / 70.0 34 2796 3350
2/0 3 x 70.0 sm / 35.0 33 2410 2950
3/0 3 x 95.0 sm / 95.0 38.5 3791 4550
3/0 3 x 95.0 sm / 50.0 38 3296 4100
4/0 3 x 120.0 sm / 70.0 41 4236 5050
4/0 3 x 120.0 sm / 120.0 42 4786 5550
300mcm 3 x 150.0 sm / 70.0 45 5100 6000
300mcm 3 x 150.0 sm / 150.0 46 5970 6900
350mcm 3 x 185.0 sm / 95.0 50 6383 7550
350mcm 3 x 185.0 sm / 185.0 51 7363 8500
500mcm 3 x 240.0 sm / 120.0 57 8242 9950
8 4 x 10.0 re / 10.0 20.5 504 890
6 4 x 16.0 re / 16.0 23.5 796 1250
4 4 x 25.0 rm / 16.0 28 1142 1800
2 4 x 35.0 sm / 16.0 29 1526 2050
1 4 x 50.0 sm / 25.0 33 2203 2700
2/0 4 x 70.0 sm / 35.0 37 3082 3750
3/0 4 x 95.0 sm / 50.0 43.5 4208 5000
4/0 4 x 120.0 sm / 70.0 47 5388 6350
300mcm 4 x 150.0 sm / 70.0 51 6540 7650
350mcm 4 x 185.0 sm / 95.0 56 8159 9350
500mcm 4 x 240.0 sm / 120.0 62.5 10546 11600


Previous:H05RVV-F Power Cable       Next:NYY Power Cables