0.6/1KV 3+2 Core CU/XLPE/STA/Polyolefin LSZH Power Cable

Release time:2018-07-05 14:28 hit:


APPLICATION
(Low Smoke Zero Halogen) LSZH Copper Conductor XLPE Insulated Polyolefin Sheathed Power Cable.
Copper XLPE Polyolefin LSZH Cable is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 0.6/1KV
 
CABLE STANDARDS
GB/T12706-2008,IEC,BS,ASTM and etc. upon request.
 
BASIC INFORMATION
Code Name 
WDZ-YJY
Rated Voltage (Uo/U)
0.6/1KV
Cable Structure
Copper Conductor/XLPE Insulation/Polyolefin Sheath
CONSTRUCTION
Conductor
Number of conductors:1,2,3,4,5,3+1,4+1
The conductors shall comply with the requirement given in IEC
Insulation
XLPE(Cross-linked Polyethylene) according to IEC
Sheath
Low Smoke Zero Halogen Polyethylene according to IEC
 
CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 90℃
Max.short-circuit temperature
Maximum shall not exceed 250℃(5s Max,Duration)
Installation temperature
Ambient temperature under installation shall not be below 0℃
Minimum bending radius
The bending radius of cable: (D-Diameter of cable) 
————————————-≥15D

Nominal Cross Sectional Area Of Conductor(mm²)
1x1.5 2x1.5 3x1.5 4x1.5 5x1.5 3x2.5+1x1.5 3x2.5+2x1.5 4x2.5+1x1.5
1x2.5 2x2.5 3x2.5 4x2.5 5x2.5 3x4+1x2.5 3x4+2x2.5 4x4+1x2.5
1×4 2×4 3×4 4×4 5×4 3x6+1x4 3x6+2x4 4x6+1x4
1×6 2×6 3×6 4×6 5×6 3x10+1x6 3x10+2x6 4x10+1x6
1×10 2×10 3×10 4×10 5×10 3x16+1x10 3x16+2x10 4x16+1x10
1×16 2×16 3×16 4×16 5×16 3x25+1x16 3x25+2x16 4x25+1x16
1×25 2×25 3×25 4×25 5×25 3x35+1x16 3x35+2x16 4x35+1x16
1×35 2×35 3×35 4×35 5×35 3x50+1x25 3x50+2x25 4x50+1x25
1×50* 2×50* 3×50* 4×50* 5×50* 3x70+1x35 3x70+2x35 4x70+1x35
1×70* 2×70* 3×70* 4×70* 5×70* 3x95+1x50 3x95+2x50 4x95+1x50
1×95* 2×95* 3×95* 4×95* 5×95* 3x120+1x70 3x120+2x70 4x120+1x70
1×120* 2×120* 3×120* 4×120* 5×120* 3x150+1x70 3x150+2x70 4x150+1x70
1×150* 2×150* 3×150* 4×150* 5×150* 3x185+1x95 3x185+2x95 4x185+1x95
1×185* 2×185* 3×185* 4×185* 5×185* 3x240+1x120 3x240+2x120 4x240+1x120
1×240* 2×240* 3×240* 4×240* 5×240* 3x300+1x150 3x300+2x150 4x300+1x150
1×300* - 3×300* 4×300* 5×300* 3x400+1x185 3x400+2x185 4x400+1x185
1×400* - 3×400* 4×400* 5×400* - - -
1×500* - 3×500* 4×500* 5×500* - - -
1×630* - - - - - - -