Product List
Hot Product
  • Low smoke low halogen flame retardant control cable
  • Shielded power cable
  • Oil Resistant Flexible Control Cable with Internati
  • Welding Cable
  • 4/6 AWG Duplex Service Drop
  • Metal shielded power cable
  • Low smoke low halogen flame r
  • Shielded power cable
  • Oil Resistant Flexible Contro
  • Welding Cable
  • 4/6 AWG Duplex Service Drop
  • Metal shielded power cable
Projects

300/300V Indoor lighting Rubber insulation woven flexible wi

Release time:2018-05-22 10:01 hit:


 


Suitable for indoor lighting, household appliances and tools for connecting AC rated voltage 300/300V and below voltage. The long term working temperature of conductor wire core should be less than 65℃.

The type and name of the wire are:
 
RXS - rubber insulated braided twin twisted flexible cable;
 
RX - rubber insulated total weaving round flexible wire;
 
RXH - rubber insulation, rubber protection layer total weaving round flexible wire.
 
RXH type flexible wire specifications and reference data:
 
Nominal cross section (mm) Wire core structure
Root number/single wire diameter (mm)
Max Outside Diameter (mm) Dc resistance (Ω/km, not larger than)
2 core 3 core No tin copper core Tin plated copper core
0.3 16/0.15 5.7 6.1 69.2 71.2
0.4 23/0.15 6.1 6.5 48.2 49.6
0.5 28/0.15 6.3 6.7 39.0 40.1
0.75 42/0.15 6.8 7.2 26.0 26.7
1 32/0.20 7.2 7.6 19.5 20.0
1.5 48/0.20 8.7 9.3 13.3 13.7
2.5 77/0.20 11.6 12.4 7.98 8.21
4 126/0.20 12.7 13.6 4.95 6.09

RX type flexible wire specifications and reference data:

 

Nominal cross section (mm) Wire core structure
Root number/single wire diameter (mm)
Max Outside Diameter (mm) Dc resistance (Ω/km, not larger than))
2 core 3 core No tin copper core Tin plated copper core
0.3 16/0.15 6.0 6.4 71.3 73.0
0.4 23/0.15 6.4 6.9 49.6 51.1
0.5 28/0.15 7.6 8.1 40.2 41.3
0.75 42/0.15 8.0 8.6 26.8 27.5
1 32/0.20 8.4 9.0 20.I 20.6
1.5

48/0.20

9.0 9.6 13.7 14.1
2.5 77/0.20 12.1 13.0 8.2 8.46
4 126/0.20 13.3 14.3 5.1 5.24

 

RXS type flexible wire specifications and reference data:

 

Nominal cross section (mm) Wire core structure Root number/diameter (mm) Wire reference data
The largest diameter (mm) Weight (kg/km) 20℃,Conductor resistance (Ω/km, not lager than)
0.3 16/0.15 2.3 6.4 69.2
0.4 23/0.15 2.5 8.1 48.2
0.5 16/0.2 2.6 9.1 39.0
0.75 24/0.2 2.8 12.2 26.0
1.0 32/0.2 3.0 15.1 19.5

 