Product List
Hot Product
  • Low smoke low halogen flame retardant control cable
  • Shielded power cable
  • Oil Resistant Flexible Control Cable with Internati
  • Welding Cable
  •  2 Core SWA Cable (Steel Wire Armoured) BS5467
  • 4/6 AWG Duplex Service Drop
  • Low smoke low halogen flame r
  • Shielded power cable
  • Oil Resistant Flexible Contro
  • Welding Cable
  • 2 Core SWA Cable (Steel Wire
  • 4/6 AWG Duplex Service Drop
Projects

XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable


XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable
Standard: IEC, BS, GB
Capacity: 2000km/m
Voltage: 450 / 750V and below
Application: Approved for direct burial, Class I, Div 2 industrial hazardous locations per NEC for UL Type TC cables. In Canada, protection may be required by inspection authority per Canadian electrical code.
   


XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable
UL Type TC-ER, CSA Type RW90 XLPE, CSA Type TC, 600V
 
XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable Product Approvals:
 
Industry Approvals:
UL 44 Type XHHW-2
UL 1277 Type TC-ER for 3 or more conductors
UL 1581
ICEA S-95-658/NEMA WC70
CSA C22.2 No. 38 RW90 XLPE
CSA C22.2 No 230 Type TC
Flame Tests Approvals:
UL 1581 VW-1
UL 1277
IEEE 383
IEEE 1202
CSA FT4
Other Compliances:
Meets EPA 10 CFR, Part 261 for leachable lead content per TCLP method
OSHA acceptable
XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable Construction:
 
Conductor:
8 AWG thru 500 kcmil bare, annealed copper per ASTM B3
Class B stranding per ASTM B8
Insulation:
Flame Retardant Cross-Linked Polyethylene (XLPE) Color Code Chart per CSA Standard C22.2
No of Cond. Color Code
2 Black, White
3 Black, Red, Blue
4 Black, Red, Blue, White
>5 All black
All conductors for all constructions are alpha-numeric printed
Ground (Bonding) Conductor:
Uninsulated bare annealed copper per ASTM B3
Class B stranding per ASTM B8
Jacket:
Flame retardant and sunlight resistant Arctic-grade Polyvinylchloride (PVC)
XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable Options:
 
Tinned copper
Class C stranding
Overall shielded multi conductors
Optional color code as specified per CSA standard C22.2 No. 38 for two to four conductor cable
Non-UL 1000 volt CSA type RW90 XLPE, CSA Type TC
Other constructions available upon request
XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable Applications:
Industrial lighting, control and signaling circuits
Permitted for Exposed Run 'ER' use in accordance with NEC for 3 or more conductors
Approved for direct burial, Class I, Div 2 industrial hazardous locations per NEC for UL Type TC cables. In Canada, protection may be required by inspection authority per Canadian electrical code.
Approved for cable in tray, industrial hazardous locations, Class I, Zone 2 and Class II, Division 2 per CEC rules 18-156 and 18-252 when used with certified HL glands.
XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable Features:
 
Rated at 90°C wet or dry
Ripcord applied to all cables with jacket thickness of 60 mils or less
Meets CSA cold impact test at -40°C
Meets ICEA and CSA cold bend test at -65°C
Meets the crush and impact requirements of Type MC

Previous:XLPE/ARCTIC-FLEX Unshielded Control Cable       Next:450/750V PVC insulation Control Cables