XLPE/ARCTIC-FLEX Unshielded Control Cable


XLPE/ARCTIC-FLEX Unshielded Control Cable
Standard: IEC, BS, GB
Capacity: 2000km/m
Voltage: 450 / 750V and below
Application: Approved for direct burial, Class I, Div 2 industrial hazardous locations per NEC for UL Type TC cables. In Canada, protection may be required by inspection authority per Canadian electrical code.
   


XLPE/ARCTIC-FLEX Unshielded Control Cable
UL Type TC-ER, CSA Type RW90 XLPE, CSA Type TC, 600V
 
XLPE/ARCTIC-FLEX Unshielded Control Cable Product Approvals:
 
Industry Approvals:
ICEA S-73-532
ICEA S-95-658/NEMA WC70
UL 44 Type XHHW-2
UL 1277 Type TC-ER for 3 or more conductors
UL 1581
CSA C22.2 No. 38 XLPE RW90
CSA C22.2 No 230 Type TC
Flame Tests Approvals:
UL 1581 VW-1
UL 1277
IEEE 383
IEEE 1202
CSA FT4
Other Compliances:
Meets EPA 10 CFR, Part 261 for leachable lead content per TCLP method
OSHA acceptable
XLPE/ARCTIC-FLEX Unshielded Control Cable Construction:
 
Conductor:
14 AWG thru 10 AWG tinned, annealed copper per ASTM B33
Class B stranding per ASTM B8
Insulation:
Flame Retardant Cross-Linked Polyethylene (XLPE) Color Code Chart per CSA Standard C22.2
 
No. of Cond. Color Code
2 Black, White
3 Black, Red, Blue
4 Black, Red, Blue, White
>5 All black
All conductors for all constructions are alpha-numeric printed
Jacket:
Flame Retardant and sunlight resistant Arctic-grade Polyvinylchloride (PVC)
XLPE/ARCTIC-FLEX Unshielded Control Cable Options:
Bare copper, class C stranding
Uninsulated ground (bonding) conductors
Overall shielded multi conductors
Optional color code as specified per CSA standard C22.2 No. 38 for two to four conductor cable
Non-UL 1000 volt CSA type RW90 XLPE, CSA Type TC
Other constructions available upon request
XLPE/ARCTIC-FLEX Unshielded Control Cable Applications:
Industrial lighting, control and signaling circuits
Approved for direct burial, Class I, Div 2 industrial hazardous locations per NEC for UL Type TC cables. In Canada, protection may be required by inspection authority per Canadian electrical code.
Permitted for Exposed Run 'ER' use in accordance with NEC for 3 or more conductors
Approved for cable in tray, industrial hazardous locations, Class I, Zone 2 and Class II, Division 2 per CEC rules 18-156 and 18-252 when used with certified HL glands.
XLPE/ARCTIC-FLEX Unshielded Control Cable Features:
 
Rated at 90°C wet or dry
Ripcord applied to all cables with jacket thickness of 60 mils or less
Meets CSA cold impact test at -40°C
Meets ICEA and CSA cold bend test at -65°C
Meets the crush and impact requirements of Type MC

Previous:Oil Resistant Control Cable Benefits       Next:XLPE/ARCTIC-FLEX Unshielded Low-Voltage Power Cable