Product List
Hot Product
  • Low smoke low halogen flame retardant control cable
  • Shielded power cable
  • Welding Cable
  • 4/6 AWG Duplex Service Drop
  • Metal shielded power cable
  • TR-XLPE Insulated URD Cable
  • Low smoke low halogen flame r
  • Shielded power cable
  • Welding Cable
  • 4/6 AWG Duplex Service Drop
  • Metal shielded power cable
  • TR-XLPE Insulated URD Cable
Projects

Single Core Cu/XLPE/AWA Cable


Single Core Cu/XLPE/AWA Cable
Standard: BS5467 and other standard
Capacity: 2000km/month
Voltage: 600/1000V
Application: mainly used in power stations, public transport systems, airports, petrochemical factories, hotels, hospitals, high-rise buildings etc.
   


Application:
Single core 600/1000V XLPE insulated PVC sheathed, armoured power cable is mainly used in power stations, public transport systems, airports, petrochemical factories, hotels, hospitals, high-rise buildings etc.
 
Single Core Cu/XLPE/AWA CableSpecification:
in accordance with BS5467
Conductors: Stranded Class 2 Copper Conductors to BS6360
Insulation: XLPE
Inner Sheath: PVC
Armoring:
Single Core: Aluminum Wire Armored (AWA)
MultiCore: Steel Wire Armored (SWA)
Outer Sheath: Black PVC
Voltage Rating: 600/1000 volts
Temp. Rating: 90℃
Core Colour: Brown
 
Electrical performance:
Conductor operating temperature 90℃
Surroundings 30℃
 
Using features:
1. Rated voltage: 600/1000V
2. No. of core: Single core
3. The highest allowed operating temperature of conductor for long-term working is 90℃. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250℃.
4. D.C. resistance of the conductor complies with the stipulations of 600/1000V, 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0℃ when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 3.5 Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius: 12D overall diameter(70mm2 -1000mm2)
 
The structural parameters:
Conductor FTX300 1RCZ1MZ1-R
Core number/cross-sectional area Number of strands/Monofilament diameter Nominal thickness of insulation Nominal thickness of sheath Outside diameter UNDER shielding Outside diameter OVER inner sheath Armoured layer diameter Total nominal diameter Weight
MM² NO./MM MM MM MM MM MM MM KG/KM
1x70 19/2.14 1.1 1.8 15.2 17.6 20.1 23.9 1400
1x95 19/2.52 1.1 1.8 17.1 19.5 22.0 25.8 1700
1x120 37/2.03 1.2 1.8 19.0 20.8 24.0 27.8 2000
1x150 37/2.25 1.4 1.8 21.0 22.8 26.0 29.8 2400
1x185 37/2.52 1.6 1.8 23.2 25.0 28.2 32.0 2800
1x240 61/2.25 1.7 1.9 26.1 27.9 31.1 35.1 3500
1x300 61/2.52 1.8 2.0 28.7 30.5 33.7 37.9 4200
1x400 61/2.85 2.0 2.1 32.5 34.3 38.3 42.7 5400
1x500 61/3.20 2.2 2.2 36.0 37.8 41.8 46.4 6500
1x630 127/2.52 2.4 2.3 40.4 42.2 46.2 51.0 8200
1x800 127/2.85 2.6 2.5 45.5 47.3 52.3 57.5 10400
1x1000 127/3.20 2.8 2.7 50.4 52.2 57.2 62.4 13000