Mine Armoured Control Cable


Mine Armoured Control Cable
Standard: MT818-1999 ISO
Capacity: 2000km/m
Voltage: 450/750 V
Application: 450/750V and below control monitoring circuit, protection circuit and power distribution equipment
   


Mine armoured control cable

MKVV series Mine control cable types:
 
MKVV PVC insulated PVC sheathed control cable for coal mine
MKVVP PVC insulated PVC sheathed braided shielding control cable for coal mine
MKVV22 Coal mine PVC insulated PVC sheathed steel belt sheathed control cable
MKVV32 Coal mine PVC insulated PVC sheathed fine steel wire armoured sheathed control cable
MKVVR PVC insulated PVC sheathed control flexible cables for coal mine
MKVVRP Coal mine PVC insulated PVC sheathed braiding shielding control flexible cable
MKVV22 Coal mine PVC insulated PVC sheathed steel tape armoured control cable
MKVV32 Coal mine PVC insulated PVC sheathed fine steel wire armoured control cable
 
This product is suitable for AC rated voltage u0/u 450/750V and below control monitoring circuit, protection circuit and power distribution equipment as connection line.
 
Characteristics:
 The long-term use of conductor temperature 70°C allowed to work, cables temperature shall not be lower than 0 °C. With control cable allowed coal mine bending radius of armoured or copper tape screened structure of cable should be no less than 12 times of cable diameter. For screened flexible cable, should be not less than 6 times of cable diameter. For those without armoured layer of cable should be no less than 6 times of cable diameter. 
 
Mine armoured control cable specification and scope:
MKVV, MKVVP, MKVVP2 (0.5, 10, 2-61 was the core) apply to weak current control system or strong electromagnetic interference area
MKVV22, MKVV32 (0.5, 10) 4-61, was the core
MKVVR (0.5-6) 2-61 was the core
MKVVRP (0.5 to 4) 2-61 was the core
MKVVP22, MKVVP2-22 (1.5, 10) 4-61 was the core
MKVVP2-22 (1.5, 10) 4-61 core was mainly used for substation of 500 KV power plant and power distribution equipment and strong electromagnetic interference area.