LV XLPE Insulated PVC Sheathed Double Steel Tape Armoured Ca


LV XLPE Insulated PVC Sheathed Double Steel Tape Armoured Ca
Standard: IEC 60502-1
Capacity: 2000km/m
Voltage: 600/1000V
Application: used in power station, public transportation passenger transport system, airports, petrochemical factories, hotels, hospitals, and other high-rise buildings wiring cable.
   


LV Cu/XLPE/DSTA/PVC armoured cableApplication:
600/1000V XLPE insulation PVC sheath double steel tape armored power cable is mainly used in power station, public transportation passenger transport system, airports, petrochemical factories, hotels, hospitals, and other high-rise buildings wiring cable.
 
Fire performance:
 
Flame retardant (single vertical cable test): EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NbN C 30-004 (cat. F1); NF C32-070-2.1 (C2); CEI 20-35/1-2; en 50265-2-1*; DIN VDE 0482-265-2-1*
 
Reduce the fire spread (vertically mounted into cable beam tests): en 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NbN C 30-004 (cat. F2); NF C32-070-2.2 (C1); CEI 20-22/3-4; en 50266-2-4*; DIN VDE 0482-266-2-4
 
Halogen: IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1;BS 6425-1*
 
Non corrosive gases: IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2; BS 6425-2*
 
The minimum smoke release: IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 
 
50268-1&2*; BS 7622-1&2*
 
No toxic gas: NES 02-713; NF C 20-454
 
LV Cu/XLPE/DSTA/PVC armoured cable structure:
 
Conductor: stranded copper
Insulation: XLPE
Filling materials: PP, PET, PVC
Armour: double steel tape armour
Outer sheath: Thermoplastic PVC compounds
 
The physical properties and thermal properties:
 
The maximum operating temperature range: 90°C for XLPE
 
Short circuit overload temperature can reach 250°C(5S)
 
The minimum bending radius: 10 x diameter
 
Structure parameter:
 
Conductor FGD400 1RVMV-R
Core number/Cross-sectional area Phase line Midcourt line Nominal conductor diameter Nominal thickness of insulation Nominal steel strip thickness Nominal thickness of sheath Total nominal diameter About weight
Strands/Monofilament diameter Strands/Monofilament diameter PHA. NEU. PHA. NEU.
MM² NO/MM NO/MM MM MM MM MM MM MM MM KGIKM
3×10+1×6 7/1.35 7/1.04 3.75 2.90 0.7 0.7 0.2 1.8 20.1 740
3×16+1×10 7/1.70 7/1.35 4.75 3.75 0.7 0.7 0.2 1.8 22.5 1,004
3×25+2×16 7/2.14 7/1.70 5.85 4.75 0.9 0.7 0.2 1.8 25.8 1,421
3×35+1×16 7/2.52 7/1.70 6.90 4.75 0.9 0.7 0.2 1.8 27.7 1,745
3×35+1×25 7/2.52 7/2.14 6.90 5.85 0.9 0.9 0.2 1.8 28.6 1,864
3×50+1×25 19/1.78 7/2.14 8.15 5.85 1.0 0.9 0.2 1.8 31.3 2,358
3×50+1×35 19/1.78 7/2.52 8.15 6.90 1.0 0.9 0.2 1.9 32.0 2.72
3×70+1×35 19/2.14 7/2.52 9.75 6.90 1.1 0.9 0.2 2.0 35.9 3166
3×70+1×50 19/2.14 19/1.78 9.75 8.15 1.1 1.0 0.2 2.0 36.8 3.341
3×95+1×50 19/2.52 19/1.78 11.4 8.15 1.1 1.0 0.5 2.1 41.4 4,611
3×120+1×70 37/2.03 19/2.14 12.8 9.75 1.2 1.1 0.5 2.3 45.6 5682
3×150+1×95 37/2.25 19/2.52 14.3 11.4 1.4 1.1 0.5 2.4 50.8 7,072
3×150+1×120 37/2.25 37/2.03 14.3 12.8 1.4 1.2 0.5 2.5 51.8 7,357
3×185+1×95 37/2.52 19/2.52 15.9 11.4 1.6 1.1 0.5 2.6 54.7 8,348
3×185+1×120 37/2.52 37/2.03 15.9 12.8 1.6 1.2 0.5 2.6 55.8 8638
3×240+1×120 61I2.25 37/2.03 18.2 12.8 1.7 1.2 0.5 2.7 61.0 10,660
3×240+1×150 61I2.25 37/2.25 18.2 14.3 1.7 1.4 0.5 2.8 62.2 11024
3×300+1×150 61I2.52 37/2.25 20.4 14.3 1.8 1.4 0.5 2.9 66.8 12,809
3×300+1×185 61I2.52 37/2.52 20.4 15.9 1.8 1.6 0.5 3.0 68.1 13,256